EFFECTIVE SOLAR POWERED STREET LIGHT SYSTEM DETERMINATION BETWEEN AC AND DC LOADS USING A DESIGNED 500W, 12V/18AH SOLAR SYSTEM
Abstract
This paper critically looked into the effectiveness of both alternate current (AC) and direct current (DC) lamps when used as street light. A solar system with 500W inverter, 12V18 AH battery was designed and constructed. This solar system has AC and DC sections. Both sections were connected to 20 W AC and 20 W DC loads. The voltage readings on the system were taking at two hours intervals. The graphs of voltage versus time were plotted. Also, bar charts were drawn to represent voltage levels at various hours. From the graphs and bar charts, the rate at which each solar system drains the system can be seen and the most effective solar system can be selected. It was noted that the solar system can sustain the DC load beyond 4 hours while the AC load cannot sustain the load beyond 4 hours. Hence, the DC solar power system conserves battery energy better than the AC solar power system.
Keywords:
Battery, energy, hours, inverter, loads, solar, system, power, voltagePublished
How to Cite
Issue
Licensing
Copyright (c) 2026 ARIYANNINUOLA A., OKONIGENE R. E.

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
